ELECTRIMOTION INC.
1484 DALE FORD RD.
DELAWARE, OH 43015
740.362.0251
ELECTRIC:
+12V input RED WIRE
GND BLACK WIRE
TACH INPUT VIOLET WIRE
OUTPUT BLUE WIRE
Output can source 4A @ 12V
OPERATION: When tach signal is input into violet wire and desired rpm is met,
the output is set*.
*8 PIN SWITCH:
Add up the dip switch values to get the rpm value.
Dip Sw on |
RPM |
1 |
6400 |
2 |
3200 |
3 |
1600 |
4 |
800 |
5 |
400 |
6 |
200 |
7 |
100 |
8 |
50 |
* 4 PIN SWITCH: position 1 is the normal output state
ON = output is normally ON, output switches to OFF at selected RPM
OFF = output is normally OFF, output switches to ON at selected RPM
*4 PIN SWITCH: position 2 is the auto shifter mode
ON = output resets at set rpm - 200
OFF = output resets under 2000 rpm
always...this will latch the output.
An RPM setting
under 2000 will reset under 300 rpm. under 300 not latched.
* 4 PIN SWITCH: positions 3 and 4 is number of cyl. option
Dip switch 2 pos |
|
|
3 |
4 |
cyl |
off |
off |
2 |
off |
on |
4 |
on |
off |
6 |
on |
on |
8 |
Power must be cycled after making
any switch setting changes.